    H05VV-F/H05VVH2-F

    Application and Description

    These cables are suited for medium mechanical stress in damp and wet environments such as refrigerators, washing machines, spin dryers and other appliances, as long as it meets applicable equipment specifications. These cables are also suited for cooking and heating apparatus, provided that the cable does not come into direct contact with the hot parts of the apparatus or with any other heat source. Further applications of this cable include: Fixed installation in furniture, partition walls, decorative covering, and in the hollow spaces of prefabricated building parts. They are not suitable for outdoor use, industrial (except clothing manufacture) or farming applications. Max operating voltage in single or three phase system is Uo/U 318/550 volts. In a direct system, max operating voltage is Uo/U 413/825 volts.

    Standard and Approval

    CEI 20-20/5 / 20-35 (EN60332-1) /20-52,

    0.5 - 2.5mm² to BS6500, 4.0mm² to BS7919, 6.0mm² generally to BS7919,

    VDE0281, CENELEC HD21.5, CE low voltage directive 73/23/EEC & 93/68/EEC, ROHS compliant

    Cable Construction

    - Bare copper fine wire conductor

    - Stranded to DIN VDE 0295 cl. 5, BS 6360 cl. 5, IEC 60228 cl. 5 and HD 383

    - PVC core insulation T12 to VDE-0281 Part 1

    - Color coded to VDE-0293-308

    - Green-yellow grounding (3 conductors and above)

    - PVC outer jacket TM2    

    Technical Characteristics

    - Working voltage : 300/500 volts

    - Test voltage : 2000 volts

    - Flexing bending radius : 7.5 x Ø

    - Static bending radius : 4 x Ø

    - Flexing temperature : -5º C to +70º C

    - Static temperature : -40º C to +70º C

    - Short circuit temperature : +160º C

    - Flame retardant : IEC 60332.1

    - Insulation resistance : 20 MΩ x km

    Cable Parameter

    AWG No. of Cores x Nominal Cross Sectional Area Nominal Thickness of Insulation Nominal Thickness of Sheath Nominal Overall Diameter Nominal Copper Weight Nominal Weight
    # × mm² mm mm mm kg/km kg/km
    H05VV-F
    18(24/32) 2 x 0.75 0.6 0.8 6.4 14.4 57
    18(24/32) 3 x 0.75 0.6 0.8 6.8 21.6 68
    18(24/32) 4 x 0.75 0.6 0.8 7.4 29 84
    18(24/32) 5 x 0.75 0.6 0.9 8.5 36 106
    17(32/32) 2 x 1.00 0.6 0.8 6.8 19 65
    17(32/32) 3 x 1.00 0.6 0.8 7.2 29 79
    17(32/32) 4 x 1.00 0.6 0.9 8.0 38 101
    17(32/32) 5 x 1.00 0.6 0.9 8.8 48 123
    16(30/30) 2 x 1.50 0.7 0.8 7.6 29 87
    16(30/30) 3 x 1.50 0.7 0.9 8.2 43 111
    16(30/30) 4 x 1.50 0.7 1.0 9.2 58 142
    16(30/30) 5 x 1.50 0.7 1.1 10.5 72 176
    14(50/30) 2 x 2.50 0.8 1.0 9.2 48 134
    14(50/30) 3 x 2.50 0.8 1.1 10.1 72 169
    14(50/30) 4 x 2.50 0.8 1.1 11.2 96 211
    14(50/30) 5 x 2.50 0.8 1.2 12.4 120 262
    12(56/28) 3 x 4.00 0.8 1.2 11.3 115 233
    12(56/28) 4 x 4.00 0.8 1.2 12.5 154 292
    12(56/28) 5 x 4.00 0.8 1.4 13.7 192 369
    10(84/28) 3 x 6.00 0.8 1.1 13.1 181 328
    10(84/28) 4 x 6.00 0.8 1.3 13.9 230 490
    10(84/28) 5 x 6.00 0.8 1.4 15.9 289 548
    H05VVH2-F
    18(24/32) 2 x 0.75 0.6 0.8 4.2 x 6.8 14.4 48
    17(32/32) 2 x 1.00 0.6 0.8 4.4 x 7.2 19.2 57
    Contact Us