Industrial Cables  

Industrial Cables Single Core Fixed Wiring Cable

0361TQ to BS 683

Application and Description
0361TQ to BS 683 cables are used for the transmission of high currents from the electric welding machine to the welding tool. they are suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.

Cable Construction

Extra fine bare/tinned copper strands
Stranding to BS 6360 class 6,or class 5 (120mm² and above)
Synthetic or paper separator over core
EPR (Ethylene Propylene Rubber) to BS7655
Chlorosulphonated Polyethylene (C.S.P.), HOFR (Heat and Oil Resistant and Flame Retardant)to BS7655 , black/ orange

0361TQ to BS 683

Technical Characteristics

Working voltage: 100/100 volts
(450V for non-welding applications if suitably protected from mechanical damage)
Test voltage: 1000 volts
Minimum bending radius: 6xOverall diameter
Operating temperature: -25º C to +85º C
Flame retardant: IEC 60332.1CS

Cable Parameter

AWG
(No of Strands/ Strand Diameter)
No. of Cores x Nominal Cross Sectional Area
#xmm²
Nominal
Thickness of Insulation mm
Nominal Thickness of Sheath mm Nominal Overall Diameter mm Nominal Weight kg/km
6(903/35) 1x16 1.2 2 11.0±0.5 230
4(1407/35) 1x25 1.4 2 12.5±0.5 325
2(1974/35) 1x35 1.4 2 14±0.5 440
1(2830/35) 1x50 1.6 2.2 16.5±0.5 600
2/0(3952/35) 1x70 1.6 2.4 18.5±0.5 830
3/0(5370/35) 1x95 1.8 2.6 21.0±0.5 1110
4/0(614/24) 1x120 1.8 2.8 23.5±0.5 1375
300 MCM (765/24) 1x150 2 3 26±0.5 1680
350 MCM (944/24) 1x185 2.2 3.2 27.5±0.5 2050
500MCM(1225/24) 1x240 2.4 3.2 30.5±0.5 2630