Robotics

Robotics

Extra Flex F4 XLPE-PVC

Code

Formation

Ext.Diam mm

CU-weight kg/km

F4A8PXC

8x2x0.09

6.3

31

F4A10PXC

10x2x0.09

6.9

36

F4A25PXC

25x2x0.09

10.4

73

APPLICATION :
Supply of Fanuc system signals.
TECHNICAL CHARACTERISTICS :
Service Voltage :
300V
Test Voltage :
1500V
Insulation Resistance :
>/= 3000 Mohm x km (at 20oC)
Capacitance :
abt. 60 pF/m at 20oC (contd. / cond.) abt. 100 pF/m at 20oC (cond. / shield)
Temperature :
service from -10oC to +80oC, storage from -40oC to + 80oC
Conductor Stranding :
extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
XLPE cross-linked polythylene
Conductors Identification :
colour code acc. DIN 47100 or other code
EMC Shield :
tinned copper braid covering >/= 85%
Taping :
special tape
Jacket :
special PVC compound colour black RAL 9005
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-803-B ASTM2 oil resistance CNOMO E.03.40.150N - NFT 46-013 for resistance to industrial oils.